DESICCANT DRYERS
CDT Series
|
|
Heatless Desiccant Compressed Air Dryers For pressure dew points of +38°F to -100°F, (+3°C to -73°C)
Meeting and Exceeding ISO 8573.1 Air Quality Classes
|
|
  |
|
|
Standard Controller Features:
- Four dew point selections
- State-of-the-art Controller
- Purge Optimizer
- Programable shut-down capabilities
- Dew point performance per ISO 8573.1
Dew Point - -100°F (-73°C) / ISO Class - 1
Dew Point - -40°F (-40°C) / ISO Class - 2
Dew Point - -4°F (-20°C) / ISO Class - 3
Dew Point - +38°F (+3°C) / ISO Class - 4
CDT Series Controller/Purge Optimizer features:
- Choice of settings 10%,20%,30%,40%,50%,60%,70% with selector switch
- Reduce the regeneration (purge) cycle to save energy under reduced air load conditions (i.e. 50% purge air at 50% load)
|
|
Optional Energy-Saving Controller Features:
- Automatic purge air management
- Linear Purge Air-to-Load Energy Savings
- Vacuum Fluorescent Text Display
- Available on Models CDT40-5400 scfm
|
|
Patented CDT Series purge saving system uses temperature sensors to match purge air requirements on the dryer.
- Linear purge-to-load matching down to 2.2% purge at 16% load conditions
|
|
Benefits:
- Uses highly reliable temperature sensors
- Regeneration occurs before the heat of adsorption is lost
- No sensor calibration required
- Service reminders
|
|
Patented Operation of Optional Energy Saving Controller
- Tower 2 goes off-line; sensor B1 takes reading
- Tower 2 regenerates; sensor B1 takes another reading
- Temperature difference is indirect measurement of load on the dryer
- Microprocessor determines temperature rise that will occur when Tower 2 goes on-line and becomes fully loaded
- Tower 2 goes on-line; sensor B2 monitors temperature
- When the calculated temperature rise occurs, Tower 2 goes off-line for regeneration
|
 |
|
CDT 590-5400 Models Standard Features:
- Left and right tower pressure gauges
- Purge pressure gauge
- Moisture indicator- alerts operator of elevated dew point
- Air operated butterfly valves and dual piston, double acting rack and pinoin actuators
- Single solenoid, four way pilot valves are wired to the controller and used to direct pilot air to the actuators of the inlet switching and purge/repressurization valves
- Check valves are soft seated for sure closure and minimal wear
|
|
|